| Melding |
Koder |
Mulig årsak |
Metode for feilretting |
| 101 - ROM Error |
1 lang
2 kort |
System ROM Checksum |
Bytt ROM, Bytt System Board |
| 101 - I/O ROM Error |
Ingen |
Option ROM Checksum |
Bytt ROM |
| 102 - System Board Failure |
Ingen |
DMA, Timers, etc.. |
Bytt System Board |
| 162 - System Options Error |
2 kort |
No Disk Drive or Disk
Failure |
Kjør Computer Setup |
| 162 - System Options Not Set |
2 kort |
Configuration Incorrect |
Kjør Computer Setup |
| 163 - Time & Date Not Set |
2 kort |
Invalid Date or Time |
Kjør Computer Setup |
| 164 - Memory Size Error |
2 kort |
Memory Config Incorrect |
Kjør Computer Setup |
| 174 - ISA Config Error |
1 kort |
PnP ISA Board Not Found |
Kjør Diagnostikk |
| 175 - ISA Config Error |
1 kort |
PnP Config Not Updated |
Kjør Computer Setup |
| 178 - Processor Config
Invalid |
Ingen |
Processor Error |
Kjør Computer Setup |
| 201 - Memory Address Error |
Ingen |
RAM Failure |
Bytt Memory, Bytt Mainboard |
| 203 - Memory Address Error |
Ingen |
RAM Failure |
Bytt Memory |
| 205 - Memory Error |
Ingen |
Cache Error |
Kjør Computer Setup |
| 206 - Secondary Cache Error |
Ingen |
Cache Controller or Memory |
Kjør Computer Setup |
| 301 - Keyboard Error |
Ingen |
Keyboard Failure |
Reconnect Keyboard, Bytt
Keyboard |
| 303 - Keyboard Controller
Failure |
Ingen |
I/O Board Controller |
Bytt Keyboard, Mouse, System
Board |
| 304 - Keyboard or System
Unit Failure |
Ingen |
Keyboard |
Bytt Keyboard, Mouse. System
Board |
| 40X - Parallel Port X
Address Assignment Conflict |
2 kort |
Both External and Internal
Ports Assigned to Port XM |
Kjør Computer Setup |
| 402 - Mono Adapter Failure |
1 lang
2 kort |
Mono Display Adapter |
Bytt Adapter |
| 501 - Display Failure |
1 lang
1 kort |
Video Display Controller |
Bytt Video Card |
| 601 - Disk Controller
Failure |
Ingen |
Diskette Controller |
Kjør Computer Setup, Check/Bytt
Cables, Bytt System Board |
| 602 - Diskette Boot |
Ingen |
Diskette in Drive A: |
Fjern Diskett |
| 605 - Diskette Drive Error |
2 kort |
Mismatch Drive Type |
Kjør Computer Setup |
| 611 - Primary Floppy Address
Conflict |
2 kort |
Configuration Failure |
Kjør Computer Setup |
| 612 - Secondary Floppy
Address Conflict |
2 kort |
Configuration Error |
Kjør Computer Setup |
| 702 - Coprocessor Detected
But Not Reported |
Ingen |
Configuration Error |
Kjør Computer Setup, Bytt
Processor, Bytt System Board |
| 703 - CMOS Reports a
Coprocessor That Has Not Been
Detected by Post |
2 kort |
Configuration Error |
Kjør Computer Setup, Bytt
Processor, Bytt System Board |
| 1151 - Com Port 1 Address
Assignment Conflict |
2 kort |
Both External and Internal
Ports Assigned to Com 1 |
Kjør Computer Setup |
| 1152 - Com Port 2 Address
Assignment Conflict |
2 kort |
Both External and Internal
Ports Assigned to Com 2 |
Kjør Computer Setup |
| 1153 - Com Port 3 Address
Assignment Conflict |
2 kort |
Both External and Internal
Ports Assigned to Com 3 |
Kjør Computer Setup |
| 1154 - Com Port 4 Address
Assignment Conflict |
2 kort |
Both External and Internal
Ports Assigned to Com 4 |
Kjør Computer Setup |
| 1720 - Intellisafe Hard Disk
Detects Imminent Failure |
Ingen |
Hard Disk is About to Fail |
Backup Data and Bytt Hard
Disk |
| 1771 - Primary Disk Port
Address Resource Conflict |
2 kort |
Internal and External HDD
Controller Both Assigned to
Secondary Address |
Kjør Computer Setup |
| 1772 - Primary Disk Port
Address Resource Conflict |
2 kort |
Internal and External HDD
Controller Both Assigned to
Secondary Address |
Kjør Computer Setup |
| 1780 - Disk 0 Failure |
Ingen |
HDD Drive / Format Error |
Kjør Computer Setup, Bytt
HDD |
| 1781 - Disk 1 Failure |
Ingen |
HDD Drive / Format Error |
Kjør Computer Setup, Bytt
the Drive |
| 1782 - Disk Controller
Failure |
Ingen |
Hard Drive Circuitry Error |
Kjør Computer Setup, Bytt
the HDD |
| 1790 - Disk 0 Failure |
Ingen |
Hard Drive or Wrong Drive
Type |
Kjør Computer Setup, Kjør
Diagnostics |
| 1791 - Disk 1 Failure |
Ingen |
Hard Drive or Wrong Drive
Type |
Kjør Computer Setup, Kjør
Diagnostics |
| 1800 - Temperature Alert |
Ingen |
Internal Temperature Exceeds
Specification |
Check all Air Vents are
Clear and Cooling Fan is
Kjørning |
| XX000Y ZZ Parity Check 2 |
Ingen |
Parity RAM Failure |
Bytt Memory, Bytt System
Board |
| Hard Drive Parameter Table
or BIOS Error - System Halted |
Ingen |
Configuration or Hardware
Failure |
Kjør Computer Setup |
| IOCHECK Active Slot X |
Ingen |
Defective Board in Slot X |
Kjør Computer Setup |
| Bus Master Timeout Slot X |
Ingen |
Defective Board in Slot X |
Kjør Computer Setup |
| No Message |
1 kort |
Power on Successful |
Ingen |
| No Message |
2 kort |
Power on Successful |
Ingen |
| Resume = F1 Key |
Ingen |
As Indicated to Continue |
Press the F1 Key |